Fujitsu Airstage Commercial Heat Pump AJY324LALBH

  • £32,221.20inc TAX
  • £26,851.00ex TAX

Available Options


  • Brand: Fujitsu
  • Product Code: AJY324LALBH

Fujitsu AIRSTAGE V-III brings new levels of power and flexibility to large air conditioning applications. The DC Inverter based system can combine up to three outdoor units, creating virtually any configuration up to a maximum connected capacity of 150 kW with 64 indoor units. The Fujitsu Airstage V-III also uses high efficiency refrigerant, which offers superior system performance and heat transfer.

  • Ideal air conditioning systems for large buildings, such us large offices or hotels
  • Multiple indoor units of various capacities and types can be connected to the outdoor units
  • Efficiency in actual operation
  • Space Saving Combination
  • Space saving and compact size
  • High static pressure of 80 Pa
  • Total refrigerant piping length 1000 m
  • Energy saving technology
  • Design flexibility
  • Compact and high performance DC twin rotary compressor
  • Non-stop oil recovery operation
  • DC Inverter control
  • Extensive range of controller options including Touch Panel Controller, BEMS interfaces
  • Easy service & Maintenance
  • 5 Years Warranty

FUJITSU AIRSTAGE VRF AJY324LALBH 34HP AIR CONDITIONING SYSTEM AJY162LALBH MASTER | AJY162LALBH SLAVE
Maximum Connectable Indoor Unit 64
Cooling indoor unit connectable capacity 50 - 135.0 kW
Power Source 3 - Phase 4 wire, 400 V 50 Hz
Cooling Capacity 100.0 kW
Heating Capacity 100.0 kW
Cooling Input Power 33.12 kW
Heating Input Power27.26 kW
Cooling EER 3.02 W/W
Heating COP 3.67 W/W
Air Flow Rate 13,700 x 2 m3/h
Cooling Sound Pressure Level 66 dB(A)
Heating Sound Pressure Level68 dB(A)
Maximum external static pressure 82 Pa
Compressor motor output 11.0 x 2 kW
Heat Exchanger Fit Blue fin
Dimension(H x W x D) 1690 x (1,240 x 2) x 765 mm
Weight 550 kg
Refrigerant charge 11.8 x 2 kg
Pipe size (Gas/Liquid) 19.05 / 34.92 mm
Cooling Operation -5 0C - 46 0C
Heating Operation -20 0C - 21 0C
Specifications are based on the following conditions
  • Cooling: Indoor temperature of 27 0CDB / 19 0CWD, and outdoor temperature of 35 0CDB / 24 0CWD.
  • Heating: Indoor temperature of 20 0CDB  (15 0CWD), and outdoor temperature of 7 0CDB / 6 0CWD.
  • Pipe length: 7,5 m; Height difference between outdoor unit and outdoor unit: 0 m.
  • When cooling operation will be conducted at outdoor air temperature below -5 0C, the outdoor unit must be installed in a position that is higher than or equal to those of indoor units.

Write a review

Note: HTML is not translated!
    Bad           Good

Tags: Fujitsu Airstage, Commercial Air Conditioning, R410A