Mitsubishi Electric PEAD-RP100JAQ/PUHZ-P100VHA4 9.4 kW

  • £2,403.34inc TAX
    £3,229.18inc TAX
  • £2,002.79ex TAX

Available Options


Mitsubishi Electric Mr. Slim Power Inverter Ceiling Concealed Ducted Heat Pump offer customers high seasonal efficiency, advanced control options and quiet operation, whilst providing greater flexibility and ease of installation

  • Reduced height - entire range only 250 mm
  • Wider range of external static pressure setting across entire range
  • Drain pump included as standard
  • 5 Years Warranty

 
MITSUBISHI ELECTRIC PEAD-RP100JAQ INDOOR UNIT
Heating nominal capacity11.2 (4.5-12.5)
Cooling nominal capacity9.4 (4.9-11.2)
Heating (UK) capacity9.5 (3.85-10.65)
Cooling (UK) capacity8.65 (4.5-10.3)
SHF (Nominal & UK)0.85
COP / EER Nominal3.61 / 3.01
SCOP / SEER (BS EN14825)3.8 / 4.6
Heating ErP energy efficiency classA
Cooling ErP energy efficiency classB
Air flow (m3/min)24-29-34
Gas pipe size5/8"
Liquid pipe size3/8"
External static pressure (dBA)35-50-70-100-150
Sound pressure level (dBA)29-34-38
Sound power level (dBA)61
Dimensions (mm)1400 x 732 x 250
Weight Unit41
Electrical supply Fed byOutdoor unit
Fuse rating HRC (A)6
Interconnecting cable No. cores4
MITSUBISHI ELECTRIC PUHZ-P100VHA4 OUTDOOR UNIT
Heating sound pressure level (dBA)54
Cooling sound pressure level (dBA)50
Cooling sound power level (dBA)70
Weight (kg)75
Dimensions (W x D x H)950 x 330+30 x 943
Electrical supply220 - 240 V, 50 Hz
PhaseSingle
Nominal heating system power input (kW)3.103
Nominal cooling system power input (kW)3.120
Nominal UK heating system power input (kW)2.76
Nominal UK cooling system power input (kW)2.58
Starting Current (A)12.0
Heating system running current (A)16.27
Cooling system running current (A)15.55
MAX system running current (A)30.65
Fuse rating (BS88) (A)32
Mains cable no cores3
MAX pipe length (m)50
MAX high difference (m)30
Charge R410A (kg)3.0

Write a review

Note: HTML is not translated!
    Bad           Good

Tags: Mitsubishi Electric, Standard Inverter, Ducted, Wide Range Static Pressure, Easy Installation, Heating and Cooling, R410A